Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
1.
Children (Basel) ; 10(8)2023 Jul 27.
Artigo em Inglês | MEDLINE | ID: mdl-37628294

RESUMO

(1) Background: Cerebral MRI plays a significant role in assessing the extent of brain injury in neonates with neonatal encephalopathy after perinatal asphyxia. Over the last decades, several MRI scoring systems were developed to enhance the predictive accuracy of MRI. The aim of this study was to validate the correlation of four established MRI scoring systems with cognitive long-term outcomes in cooled asphyxiated newborns. (2) Methods: Forty neonates with neonatal encephalopathy treated with therapeutic hypothermia were included in this retrospective study. The MRI scans from the second week of life were scored using four existing MRI scoring systems (Barkovich, NICHD, Rutherford, and Weeke). The patients' outcome was assessed with the Bayley Scales of Infant Development (BSID-III) at the age of 2 years. To evaluate the correlation between the MRI scoring system with the cognitive scores of BSID-III, the correlation coefficient was calculated for each scoring system. (3) Results: All four MRI scoring systems showed a significant correlation with the cognitive scores of BSID-III. The strongest correlation was found between the Weeke Score (r2 = 0.43), followed by the Rutherford score (r2 = 0.39), the NICHD score (r2 = 0.22), and the Barkovich score (r2 = 0.17). (4) Conclusion: Our study confirms previously published results in an independent cohort and indicates that the Weeke and Rutherford scores have the strongest correlation with the cognitive score of BSID-III in cooled asphyxiated newborns.

2.
Arch Dis Child Fetal Neonatal Ed ; 105(2): 190-195, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-31248963

RESUMO

OBJECTIVE: To determine if survival rates of preterm infants receiving active perinatal care improve over time. DESIGN: The German Neonatal Network is a cohort study of preterm infants with birth weight <1500 g. All eligible infants receiving active perinatal care are registered. We analysed data of patients discharged between 2011 and 2016. SETTING: 43 German level III neonatal intensive care units (NICUs). PATIENTS: 8222 preterm infants with a gestational age between 22/0 and 28/6 weeks who received active perinatal care. INTERVENTIONS: Participating NICUs were grouped according to their specific survival rate from 2011 to 2013 to high (percentile >P75), intermediate (P25-P75) and low (

Assuntos
Lactente Extremamente Prematuro , Unidades de Terapia Intensiva Neonatal/estatística & dados numéricos , Assistência Perinatal/métodos , Assistência Perinatal/estatística & dados numéricos , Mortalidade Perinatal/tendências , Causas de Morte , Comorbidade , Feminino , Idade Gestacional , Nível de Saúde , Humanos , Lactente , Recém-Nascido , Recém-Nascido de muito Baixo Peso , Masculino , Estudos Prospectivos , Melhoria de Qualidade , Fatores de Risco , Fatores Sexuais , Centros de Atenção Terciária
3.
Thorac Cardiovasc Surg ; 67(S 04): e1-e10, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31675756

RESUMO

BACKGROUND: Even after successful aortic coarctation (CoA) repair, hypertension causes premature morbidity and mortality. The mechanisms are not clear. The aim was to evaluate elastic wall properties and aortic morphology and to correlate these results with severity of restenosis, hypertension, aortic arch geometry, noninvasive pressure gradients, and time and kind of surgical procedure. METHODS: Eighty-nine patients (17 ± 6.3 years) and 20 controls (18 ± 4.9 years) were examined using magnetic resonance imaging (MRI). In addition to contrast-enhanced MR angiography and flow measurements, CINE MRI was performed to assess the relative change of aortic cross-sectional areas at diaphragm level to calculate aortic compliance (C). RESULTS: Fifty-four percent of all patients showed hypertension (> 95th percentile), but more than half of them had no significant stenosis (defined as ≥30%). C was lower in CoA than in controls (3.30 ± 2.43 vs. 4.67 ± 2.21 [10-5 Pa-1 m-2]; p = 0.024). Significant differences in compliance were found between hyper- and normotensive patients (2.61 ± 1.60 vs. 4.11 ± 2.95; p = 0.01), and gothic and Romanesque arch geometry (2.64 ± 1.58 vs. 3.78 ± 2.81; p = 0.027). There was a good correlation between C and hypertension (r = 0.671; p < 0.01), but no correlation between C (and hypertension) and time or kind of repair, restenosis, or pressure gradients. CONCLUSION: The decreased compliance, a high rate of hypertension without restenosis, and independency of time and kind of repair confirm the hypothesis that CoA may not be limited to isthmus region but rather be a widespread (systemic) vascular anomaly at least in some of the CoA patients. Therefore, aortic compliance should be assessed in these patients to individually tailor treatment of CoA patients with restenosis and/or hypertension.


Assuntos
Aorta/diagnóstico por imagem , Coartação Aórtica/diagnóstico por imagem , Pressão Arterial , Hipertensão/diagnóstico por imagem , Angiografia por Ressonância Magnética , Imagem Cinética por Ressonância Magnética , Rigidez Vascular , Adolescente , Adulto , Anti-Hipertensivos/uso terapêutico , Aorta/anormalidades , Aorta/fisiopatologia , Aorta/cirurgia , Coartação Aórtica/complicações , Coartação Aórtica/fisiopatologia , Coartação Aórtica/cirurgia , Pressão Arterial/efeitos dos fármacos , Criança , Pré-Escolar , Feminino , Humanos , Hipertensão/tratamento farmacológico , Hipertensão/etiologia , Hipertensão/fisiopatologia , Masculino , Valor Preditivo dos Testes , Prognóstico , Estudos Prospectivos , Fatores de Risco , Rigidez Vascular/efeitos dos fármacos , Adulto Jovem
4.
Respiration ; 97(2): 108-118, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30293066

RESUMO

BACKGROUND: Congenital cardiovascular malformations (CCVM) may cause infrequently airway pathologies (AP) in children and are of prognostic and therapeutic relevance. While computed tomography (CT) is considered first-line imaging modality in many centres, we started using magnetic resonance imaging (MRI) more and more in the last years to detect CCVM and AP to avoid radiation in this patient group. OBJECTIVE: The aim of this retrospective study was to determine and to compare the diagnostic accuracy of CT and MRI when used to detect CCVM and/or AP. METHODS: All patients suspected to have CCVM and/or AP and examined either by CT or MRI between 2000 and 2013 in our hospital were included. Extension and type of CCVM, as well as their relationship to esophagus, trachea or bronchi were assessed and related to findings of tracheobronchoscopy, cardiac catheterization or surgery if available. RESULTS: One hundred six patients (median [range] 4 years [2 days to 66 years]) were examined by CT (n = 27) or MRI (n = 79). In 78 patients (74%), CCVM and/or AP were found with either of the imaging methods. CCVM were found in 63 subjects. Forty-six of 63 subjects had both, CCVM and AP. The presence of CCVM was always detected correctly by CT or MRI, although both techniques had a weakness detecting atretic segments directly. AP (n = 61) were correctly diagnosed in all patients not intubated for artificial ventilation by CT (n = 17) and in all but 2 patients by MRI (39 out of 41). CONCLUSIONS: MRI is sensitive to detect CCVM associated with AP equally to CT without any radiation exposure.


Assuntos
Cardiopatias Congênitas/diagnóstico por imagem , Imageamento por Ressonância Magnética , Tomografia Computadorizada Multidetectores , Anel Vascular/diagnóstico por imagem , Adolescente , Adulto , Idoso , Broncopatias/diagnóstico por imagem , Criança , Pré-Escolar , Constrição Patológica/diagnóstico por imagem , Esôfago/diagnóstico por imagem , Feminino , Humanos , Imageamento Tridimensional , Lactente , Recém-Nascido , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Traqueia/diagnóstico por imagem , Estenose Traqueal/diagnóstico por imagem , Traqueobroncomalácia/diagnóstico por imagem , Adulto Jovem
5.
J Cardiovasc Magn Reson ; 19(1): 8, 2016 Dec 05.
Artigo em Inglês | MEDLINE | ID: mdl-28103933

RESUMO

BACKGROUND: The objective assessment of global and regional cardiac function in children has shown to be clinically relevant but is challenging to conduct. Cardiovascular magnetic resonance (CMR) has emerged as a valuable diagnostic modality especially in patients with cardiomyopathy or congenital heart disease. However, data on the normal cardiac deformation in children assessed by CMR is lacking at present. Thus, the aim of this study was to provide reference values for cardiac strain and strain rate in children and adolescents derived from CMR feature tracking (FT) measurements. METHODS: In this binational study, eighty children and adolescents (age 0.4-18.0 years, 41 male, 39 female) free from cardiac diseases from two centers underwent CMR in 1.5 T whole-body scanners in supine position. Global peak radial, circumferential and longitudinal systolic strains as well as the corresponding early peak diastolic strain rates were assessed applying FT on short axis as well as 3- and 4-chamber views of standard cine steady-state free precession images. RESULTS: The difference between genders yielded no significance for all assessed strains. Yet, all strains showed a significant parabolic relation to age and an even stronger one to body surface area (BSA). Therefore, BSA-specific reference values were determined using a polynomial regression model. The apical cardiac segments featured significant higher peak circumferential but lower peak radial systolic strains than the midventricular and basal segments (all p < 0.001). CONCLUSIONS: The assessment of cardiac deformation by CMR-FT is feasible in children. This is the first CMR study providing specific reference values for FT-derived strain and strain rate in the pediatric age range.


Assuntos
Ventrículos do Coração/diagnóstico por imagem , Imagem Cinética por Ressonância Magnética/normas , Contração Miocárdica , Função Ventricular Esquerda , Adolescente , Fatores Etários , Fenômenos Biomecânicos , Criança , Pré-Escolar , Feminino , Alemanha , Humanos , Lactente , Masculino , Países Baixos , Variações Dependentes do Observador , Posicionamento do Paciente , Valor Preditivo dos Testes , Padrões de Referência , Reprodutibilidade dos Testes , Estresse Mecânico , Decúbito Dorsal , Imagem Corporal Total
6.
J Pediatr Endocrinol Metab ; 27(9-10): 915-22, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-24854524

RESUMO

AIM: The aim of this study was to evaluate the morphology and elastic properties of the aorta in children and adolescents with Ullrich-Turner syndrome (UTS) treated with growth hormone, by using magnetic resonance imaging (MRI). METHODS: Thirty-seven conscious UTS patients were examined using a 1.5-T whole-body MRI. Contrast-free three-dimensional (3D)-MR angiographies were performed, including 2D cine MRI, to calculate the aortic compliance (C) and cine of the aortic valve. RESULTS: Changes of aortic morphology were evident in 40% of the patients, whereas six had more than one alteration. A bicuspid aortic valve was identified in three patients that were missed by previous echocardiography. The aortic compliances in UTS patients were similar to those in healthy persons. CONCLUSION: This study shows that aortic morphology and compliance can be assessed by MRI without using contrast agents and without sedation in children and adolescents with UTS.


Assuntos
Aorta/patologia , Imageamento por Ressonância Magnética , Síndrome de Turner/patologia , Adolescente , Aortografia , Criança , Estudos Transversais , Feminino , Humanos , Masculino , Estudos Prospectivos , Síndrome de Turner/diagnóstico por imagem
7.
Catheter Cardiovasc Interv ; 72(4): 544-51, 2008 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-18814228

RESUMO

OBJECTIVE: To evaluate varying CT settings to visualize pediatric vascular stents in comparison to digital angiography (DA). BACKGROUND: There is a great clinical interest in substituting noninvasive methods to follow up children with congenital heart disease after interventional treatment. MATERIALS AND METHODS: CT studies in small children with transcatheter placed stents were reviewed, retrospectively. Furthermore, eight stents were implanted in tubes and partially obstructed. CT exams were performed on varying scanners (4 up to 64 slices) with corresponding tube settings. The effects of dose on image quality were evaluated regarding stent size, strut thickness, and in-stent stenoses in comparison to DA. RESULTS: Fourteen children with 28 implanted stents were identified. Significant differences between higher and lower radiation settings were not found, corresponding with the phantom, where moderate tube setting showed the best results. In vitro, there was an improvement with increasing number of detector rows, which resulted in a decrease of stent strut overestimation (295% down to 201%; P < 0.0001) and a better agreement with DA measurements for mild (78% up to 91%; P = 0.003) and moderate in-stent stenoses (80% up to 99%; P = 0.0001). CONCLUSION: Higher radiation exposure settings did not improve image quality, suggesting that the exams could be performed at a lower radiation dose.


Assuntos
Angiografia Digital , Cateterismo Cardíaco/instrumentação , Angiografia Coronária/métodos , Oclusão de Enxerto Vascular/diagnóstico por imagem , Cardiopatias Congênitas/terapia , Radiografia Intervencionista/métodos , Stents , Tomografia Computadorizada por Raios X , Artefatos , Cateterismo Cardíaco/efeitos adversos , Pré-Escolar , Constrição Patológica , Estudos de Viabilidade , Feminino , Oclusão de Enxerto Vascular/etiologia , Cardiopatias Congênitas/diagnóstico por imagem , Humanos , Lactente , Masculino , Imagens de Fantasmas , Valor Preditivo dos Testes , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador , Estudos Retrospectivos
8.
AJR Am J Roentgenol ; 190(5): 1241-6, 2008 May.
Artigo em Inglês | MEDLINE | ID: mdl-18430838

RESUMO

OBJECTIVE: The purpose of our study was to assess the visibility of lumen narrowing of pediatric vascular stents using various CT dose parameters in an in vitro model. MATERIALS AND METHODS: Ten steel stents of varying designs and sizes commonly used in the treatment of congenital heart disease were implanted in polyvinyl chloride (PVC) tubes and three of the 10 stents were partially obstructed with wax by filling 25% (mild) to 60% (moderate) of the lumen with contrast material. On a 64-MDCT scanner, the stents were scanned at tube voltages (kVp) of 80, 100, and 120 and at tube currents (mA) of 40, 80, 120, and 160. CT measurements of inner-stent diameter, strut thickness, and percent lumen (in-stent) stenoses were compared with biplane fluoroscopy of digital angiography. RESULTS: The stent diameter and percent stenosis on all CT images were consistently smaller than measured on digital angiography but were highly correlated (r = 0.97; p < 0.0001) with improvement as stent diameter increased (93% agreement with digital angiography for 4-mm stent, up to 99% for 25-mm stent; p = 0.001). Moderate stenosis could be assessed better than mild stenosis (99% vs 91% agreement with digital angiography; p = 0.003). Increasing exposure settings improved CT correlation of all measurements for mA up to 120 and kVp up to 100 (98.1% agreement). Higher settings did not improve accuracy (93.9% for 160 mA at 120 kVp; p = 0.03). CONCLUSION: CT is feasible to assess lumen narrowing of pediatric vascular stents at a wide range of tube settings. The study suggests that it is possible to lower the radiation exposure settings without loss in image quality or accuracy in detecting in-stent stenoses.


Assuntos
Oclusão de Enxerto Vascular/diagnóstico por imagem , Cardiopatias Congênitas/diagnóstico por imagem , Cardiopatias Congênitas/cirurgia , Stents , Tomografia Computadorizada por Raios X , Artefatos , Implante de Prótese Vascular , Criança , Angiografia Coronária , Desenho de Equipamento , Humanos , Modelos Cardiovasculares
9.
Catheter Cardiovasc Interv ; 68(1): 11-20, 2006 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-16764005

RESUMO

OBJECTIVES: Our purpose was to investigate the diagnostic reliability of multi-detector computed tomography (MDCT) in assessing in-stent stenosis compared to digital angiography (DA) in small children. BACKGROUND: Little is known about the feasibility of using MDCT to assess stents placed to treat children with congenital heart disease (CHD). METHODS: Twenty-two children (median age [range], 2(3/4) [(1/2) to 12] years) with 42 transcatheter placed stents (median diameter: 7.2 [3.4-16.3] mm) in the pulmonary arteries (n = 36), aorta (2), PDA (1), and SVC (3) underwent both MDCT and DA due to suspected hemodynamic problems. RESULTS: Independent "blinded" observers were able to measure stent and minimal luminal diameters in 115 out of 124 (93%) stent segments on MDCT and DA. The interobserver variability was low (mean difference: 0.5, SD 0.8 mm) with high correlation (r = 0.97; P < .0001). The percent stenosis by MDCT correlated well with DA (r = 0.89, P < .0001; mean error 2.7, SD 10.4%). For all grades of stenosis, the sensitivity and specificity for MDCT were 58% and 97%, respectively. At a threshold of approximately > or =20% stenosis sensitivity became >98%. All stent associated complications [fracture (4), vascular narrowings (11)] were diagnosed by MDCT. As the stent diameter increased, there was significantly reduced variability between MDCT and DA for in-stent stenosis (P < .0001). CONCLUSION: In small children, MDCT is a feasible and promising method for assessing stent associated complications in the treatment of CHD. Cardiac surgeons and interventional cardiologists might rely on this imaging modality to plan specific interventions more precisely and to assess the results upon follow up.


Assuntos
Oclusão de Enxerto Vascular/diagnóstico por imagem , Cardiopatias Congênitas/diagnóstico por imagem , Stents , Tomografia Computadorizada por Raios X , Angiografia Digital , Aortografia , Cateterismo , Criança , Pré-Escolar , Constrição Patológica/diagnóstico por imagem , Canal Arterial/diagnóstico por imagem , Estudos de Viabilidade , Feminino , Cardiopatias Congênitas/terapia , Humanos , Lactente , Masculino , Variações Dependentes do Observador , Valor Preditivo dos Testes , Falha de Prótese , Artéria Pulmonar/diagnóstico por imagem , Projetos de Pesquisa , Estudos Retrospectivos , Índice de Gravidade de Doença , Grau de Desobstrução Vascular , Veia Cava Superior/diagnóstico por imagem
10.
Catheter Cardiovasc Interv ; 67(3): 477-81, 2006 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-16475177

RESUMO

The case report demonstrates the value of multslice computed tomography for stent imaging and detection of an in-stent stenosis in an infant with pulmonary atresia and ventricular septal defect after stent placement in the right pulmonary artery after biventricular repair.


Assuntos
Oclusão de Enxerto Vascular/diagnóstico por imagem , Cardiopatias Congênitas/terapia , Atresia Pulmonar/terapia , Stents , Tomografia Computadorizada por Raios X/métodos , Angiografia Digital , Angiografia Coronária , Cardiopatias Congênitas/diagnóstico por imagem , Humanos , Lactente , Atresia Pulmonar/diagnóstico por imagem
11.
Int J Cardiol ; 113(3): 291-8, 2006 Nov 18.
Artigo em Inglês | MEDLINE | ID: mdl-16377005

RESUMO

BACKGROUND: Previous studies have suggested the feasibility of a non-invasive quantification of vascular trans-stenotic pressure gradients (DeltaP) by phase-contrast MR imaging (PC-MRI). Our purpose was to assess the value of MRI estimated pressure gradients as a screening tool for assessing hemodynamically significant (re-)coarctation of the aorta (CoA) in pediatric patients. METHODS: Forty-three patients (median age (range), 16 (5-25) years) with CoA (38 postoperative and 5 native) and clinically suspected hemodynamically significant stenosis underwent quantitative and semi-quantitative PC-MRI blood flow measurements and 3D MR-angiography, Doppler ultrasound (US) and conventional catheter angiography (CCA, n=20). Estimated DeltaP for each modality was correlated with percent stenosis. RESULTS: The percent stenosis correlated only moderately with DeltaP(MRI) (r=0.55, p<0.001) and DeltaP(CCA) (r=0.48, p<0.001). Only moderate correlations were observed between DeltaP(MRI) vs. DeltaP(CCA) (r=0.54, p=0.02) and vs. DeltaP(US) (r=0.40, p=0.01). In contrast, semi-quantitative analysis of PC-MRI flow profiles predicted with good sensitivity (88%) and specificity (88%) who would be operated on. Thirteen patients met hemodynamic and percent stenosis criteria by CCA for surgical intervention. CONCLUSION: Measured pressure gradients using PC-MRI should be used cautiously when assessing patients for recoarctation of the aorta. The analysis of blood flow profiles by PC-MRI might be a promising alternative in assessing the hemodynamic significance of CoA.


Assuntos
Coartação Aórtica/diagnóstico , Coartação Aórtica/fisiopatologia , Imageamento por Ressonância Magnética , Adolescente , Adulto , Coartação Aórtica/diagnóstico por imagem , Criança , Pré-Escolar , Feminino , Seguimentos , Humanos , Masculino , Estudos Prospectivos , Radiografia , Recidiva , Fluxo Sanguíneo Regional
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...